ÑÁÂÃíãä 12x1 ÒÓ Ó 31.3-00214534-008-2001 |
| Signal blocking cables with copper conductors, with polyethylene insulation, in PVC compound sheath, with low smoke and corrosive gas emission |
| Designed for electrical installations of railway signaling, centralization, blocking and automation at a rated voltage of 380 V AC at frequency 50 Hz or 700 V DC |
|
|
|
| Cables are used for laying: |
| • in bunches |
| • in premises, dry ducts and tunnels, in corrosive environment |
| • at the sites, where, along with the requirements for flame retardance are specified requirements for low smoke and gas emission at combustion or smoldering |
| • in the absence of mechanical effects on cable |
|
|
|
| Manufacturing of cables with core diameter of 0.8 mm is possible |
|
|
|
| Fire safety code in accordance with ÄÑÒÓ 4809:2007: ÏÁ123121000 |
| Products of this mark meet the requirements: |
| • single wire cable flame retardance |
| • bunched cable flame retardance category A |
| • toxicity class Tk3 of the combustion products of nonmetallic elements (toxicity index over 120 g/m3) |
| • class ÄÒê1 on smoke-forming ability by smouldering of non-metallic elements (coefficient of smoke formation from 50 to 500 m2/kg) |
| • class ÄÏê2 on smoke-forming ability by combustion (minimum luminous flux more than 60 %) |
| • corrosive class Êê1 of combustion products of non-metallic elements (the number of halogen hydrides less than 150 mg/g, pH less than 4.3, specific conductivity more than 10 µS/mm) |